Forstærkermoduler

Renkus-Heinz

Vejl. ud. kr 4.595

PF1-200

Power: 200 W RMS @ 4Ω, 300 W Burst  
Frequency Response: +0.0, -.5 dB, 20 Hz to 20 kHz
THD Distortion: < 0.02% typical
Hum & Noise : <100 dB (A weighted)
Damping: >100
Input: 10K Ohm balanced differential
Sensitivity: 1.0 V for RPO
CMR: 74 dB  
Controls: Gain (screwdriver adjustable)
Connectors: Input: Looping XLR; female in, male out
  (pin 1 chassis, pin 2 +, pin 3 -)
Power: Power: EC Power connector
  Universal 90–260 VAC, 50/60Hz.
  2.4A@120 V, 1.2A@240V
  Idle current: 200 mA@120V;100 mA@240V
  Max inrush current: 1 A


PF1-500

Power: 500 W RMS @ 4Ω, 500 W Burst 
Frequency Response: +0.0, -.5 dB, 20 Hz to 20 kHz
THD Distortion: < 0.02% typical
Hum & Noise : <100 dB (A weighted)
Damping: >100
Input: 10K Ohm balanced differential
Sensitivity: 1.0 V for RPO
CMR: 74 dB 
Controls: Gain (screwdriver adjustable)
Connectors: Input: Looping XLR; female in, male out
  (pin 1 chassis, pin 2 +, pin 3 -)
Power: Power: EC Power connector
  Universal 90–260 VAC, 50/60Hz.
  5A@120 V, 2.5A@240V
  Idle current: 400 mA@120V;200 mA@240V
  Max inrush current: 1 A


PF1-200-RHA

The PF1-200R is identical to the PF1-200 except for the addition of the RHAON Network Interface. Additional capabilities include:

Inputs: Cobranet; dual RJ45 connectors;accept
  Cat e5 copper cable.
  AES/EBU; Phoenix connectors.
  Analog; Phoenix connectors.   
Digital Format:  16 or 24 bit PCM; 48 or 96 kHz sample rate;
  selectable Network Latency.   
Protection: Soft & Peak Limiting, Excursion Control &
  Thermal Regulation.


PF1-500-RHA

The PF1-500R is identical to the PF1-500 except for the addition of the RHAON Network Interface. Additional capabilities include:

Inputs: Cobranet; dual RJ45 connectors;accept
  Cat e5 copper cable.
  AES/EBU; Phoenix connectors.
  Analog; Phoenix connectors.   
Digital Format:  16 or 24 bit PCM; 48 or 96 kHz sample rate;
  selectable Network Latency.    
Protection: Soft & Peak Limiting, Excursion Control &
  Thermal Regulation.


PF2-500-RHAON

The PF2-500R is a RHAON empowered 500/200 Watt biamplifier. It is identical to the PF1-500R except for also having a 200 Watt HF amplifier and associated electronic crossover.

Inputs:
Cobranet; dual RJ45 connectors;accept
  Cat e5 copper cable.
  AES/EBU; Phoenix connectors.
  Analog; Phoenix connectors.    
Digital Format:
  16 or 24 bit PCM; 48 or 96 kHz sample rate;
  selectable Network Latency.    
Protection:
Soft & Peak Limiting, Excursion Control &
  Thermal Regulation.
Power: 6A@120V, 3A@240V
  Idle current: 500 mA @ 120 V; 250 mA @ 240


PN-1

POWER RATING: 300 Watts RMS @ 8 Ohms
FREQUENCY RESPONSE: +0.0, -.5 dB, 20 Hz to 20 kHz
THD DISTORTION: < 0.02% typical
HUM & NOISE: <100 dB (A weighted)
DAMPING: <100
INPUT: 10 KOhm balanced differentialV for RPO
SENSITIVITY: 1.o V for RPO
CMR: 74 dB
CONTROLS: Gain (screwdriver adjustable)
POWER REQUIREMENTS: 90-136 VAC or 180-260 VAC, 50/60 Hz
4 Amps @ 120 V, 2 Amps @ 240 V
Idle Current: 300 mA@120V; 150@240V
Max Inrush Current: 10 Amps

CONNECTORS
   
INPUT: Looping XLR; Female In, Male Out (pin1 chassis, pin2+, pin 3 -)
POWER: EC Power Connector


PN-1R

The PN-1R amplifier is identical to the PN-1 except for the addition of the RHAON Network Interface; additional capabilities include:

INPUTS: CobraNet; dual RJ45 connectors;accept
CAT 5 copper cable.
AES/EBU; Phoenix connectors Analog; Phoenix connectors
DIGITAL FORMAT: 16 or 24 bit PCM; 48 or 96 kHz sample rate; selectable Network Latency.
HUM & NOISE: <100 dB (A weighted)
PROTECTION: Soft & Peak Limiting, Excursion Control & Thermal Regulation


PM1L-RHA

POWER RATINGS (Watts) Lows:  850 RMS, 950 Pgm, 1200 Peak (20 ms)
FREQUENCY RESPONSE: +0.0,-.5 db, 20Hz to 2kHz
THD DISTORSION: <0,01% typical
HUM & NOISE: <100 dB (refered to RPO@4Ohms)
INPUT SENSITIVITY: 1,4V for RPO
DAMPING FACTOR:
135 (100 Hz to 400Hz)
POWER CONNECTOR: PowerCon locking connector
POWER REQUIREMENTS: 90-136 VAC or 180-260 VAC, 50/60Hz
  6.7Amps@120V, 2.3Amps@240V
Idle Current: 380mA@120V, 190mA@240V


ANALOG INPUT (STANDARD) 50K Ohm balanced differential input
Connectors: Input; female XLR, Looping; male XLR  (pin 1 chassis, pin 2+, pin 3 signal)
Common Mode Rejection: >90dB, 30Hz to 2kHz
Controls: Rotary Gain, LF, MF, HF Mute Buttons
Options: Optional Jensen input transformer
COBRANET INPUT: CobraNet input on two RJ45 connectors for redundancy
Channels: 6 analog (1 dedicated to loudspeakers) selectable
  from 4 CobraNet bundles (32 Channels)
R-CONTROL CARD: Input: RJ4 connector
Gain Control: Rocker switch on panel + computer control
Mute Buttons: Independent LF, MF, HF Mute Buttons on panel + computer control
Computer Control & Monitoring: Computer Supervision & Control of: Gain, Polarity, Mute, Input-Output VU Meters,
  Heatsink Temperature, Groups, Scenes, Error Logs, Alarms


PM2L-RHA

POWER RATINGS Lows (Watts): 1700 RMS, 950 Pgm, 2400 Peak (20 ms)
FREQUENCY RESPONSE: +0.0,-.5 db, 20Hz to 2kHz
THD DISTORSION: <0,01% typical
HUM & NOISE: <100 dB (refered to RPO@4Ohms)
INPUT SENSITIVITY: 1,4V for RPO
DAMPING FACTOR: 135 (100 Hz to 400Hz)
POWER CONNECTOR: PowerCon locking connector
POWER REQUIREMENTS: 90-136 VAC or 180-260 VAC, 50/60Hz 10.5Amps@120V, 5.2Amps@240V
Idle Current: 380mA@120V, 190mA@240V

 
ANALOG INPUT (STANDARD) 50K Ohm balanced differential input
Connectors: Input; female XLR, Looping; male XLR
  (pin 1 chassis, pin 2+, pin 3 signal)
Common Mode Rejection: >90dB, 30Hz to 2kHz
Controls: Rotary Gain, LF, MF, HF Mute Buttons
Options: Optional Jensen input transformer
COBRANET INPUT: CobraNet input on two RJ45 connectors for redundancy
Channels: 6 analog (1 dedicated to loudspeakers) selectable
  from 4 CobraNet bundles (32 Channels)
R-CONTROL CARD: Input: RJ4 connector
Gain Control: Rocker switch on panel + computer control
Mute Buttons: Independent LF, MF, HF Mute Buttons on panel +
  computer control
Computer Control & Monitoring: Computer Supervision & Control of:
  Gain, Polarity, Mute, Input-Output VU Meters,  Heatsink Temperature, Groups, Scenes, Error Logs,  Alarms


PM2-RHAON (2-Channel)

POWER RATINGS: (Watts)  
Mids: 425 RMS, 475 Pgm, 600 Peak (20 ms)
Highs: 175 RMS, 200 Pgm, 250 Peak (20 ms)
FREQUENCY RESPONSE: +0.0,-.5 db, 20Hz to 20kH
THD DISTORSION: <0,01% typical
HUM & NOISE: <100 dB (refered to RPO@4Ohms)
INPUT SENSITIVITY: 1,4V for RPO
DAMPING FACTOR: 100 (400Hz to 2kHz)   100 (2kHz and up)
POWER CONNECTOR: PowerCon locking connector
POWER REQUIREMENTS: 90-136 VAC or 180-260 VAC, 50/60Hz
  6.5Amps@120V, 2.2Amps@240V
Idle Current: 380mA@120V, 190mA@240V


ANALOG INPUT (STANDARD) 50K Ohm balanced differential input
Connectors: Input; female XLR, Looping; male XLR
  (pin 1 chassis, pin 2+, pin 3 signal)
Common Mode Rejection: >90dB, 30Hz to 2kHz
Controls: Rotary Gain, LF, MF, HF Mute Buttons
Options: Optional Jensen input transformer
COBRANET INPUT: CobraNet input on two RJ45 connectors for redundancy
Channels: 6 analog (1 dedicated to loudspeakers) selectable
  from 4 CobraNet bundles (32 Channels)
R-CONTROL CARD: Input: RJ4 connector
Gain Control: Rocker switch on panel + computer control
Mute Buttons: Independent LF, MF, HF Mute Buttons on panel +
  computer control
Computer Control & Monitoring: Computer Supervision & Control of:
  Gain, Polarity, Mute, Input-Output VU Meters, Heatsink Temperature, Groups, Scenes, Error Logs, Alarms


PM3-RHAON (3-Channel)